Sports field irrigation - Impact- or gear drive valve-in-head pop-up sprinkler

Irrigation sequence:
7 irrigation sections
- 2 sprinklers each at the sidelines
- 1 sprinkler in the centre of the field
Flow rate:
TRITON-L
1 sprinkler at the sideline
Q= 9,5 m³/h
1 sprinkler in the centre of the field
Q= 17,2 m³/h
Max. flow rate per irrigation section
Q= 19,0 m³/h
Flow rate:
HYDRA-2-M
1 sprinkler at the sideline
Q= 9,2 m³/h
1 sprinkler in the centre of the field
Q= 9,2 m³/h
Max. flow rate per irrigation section
Q= 18,4 m³/h
Operating pressure:
Pressure at the sprinkler nozzle
H = 6,0 bar
Required flow pressure at the connection terminal for a water intake of 19,0 m³/h
H = 8,0 bar
Precipitation:
TRITON-L
Average precipitation density
2,5 mm/h
Precipitation:
HYDRA-2-M
Average precipitation density
2,7 mm/h
No. of sprinklers:
Lateral sprinkler: TRITON-L WVAC / HYDRA-2-M WVAC
10 pieces
Midfield sprinkler: TRITON-L SVAC / HYDRA-2-M SVAC
2 pieces
Controller: WaterControl+ SC 8 stations
1 piece

Stadium/arena irrigation - Impact valve-in-head pop-up sprinkler

Irrigation sequence:
9 irrigation sections
- 2 sprinklers each at the sidelines
- 1 sprinkler in the centre of the field
Flow rate:
1 sprinkler at the sideline
Q= 9,5 m³/h
1 sprinkler in the centre of the field
Q= 17,2 m³/h
Max. flow rate per irrigation section
Q= 19,0 m³/h
Operating pressure:
Pressure at the sprinkler nozzle
H = 6,0 bar
Required flow pressure at the connecting terminal for a water intake of 19,0 m³/h
H = 8,0 bar
Precipitation:
Average precipitation density
2,5 mm/h
No. of sprinklers:
Lateral sprinkler: TRITON-L WVAC
12 pieces
Mittelfeldregner: TRITON-L TCVAC
3 pieces
Steuergerät: WaterControl+ SC 12 Kreise
1 piece

Stadium/arena irrigation - gear drive valve-in-head pop-up sprinklers and solenoid valves at the sideline

Irrigation sequence:
9 irrigation sections
- 2 sprinkler each at the sidelines
- 2 sprinkler in the centre of the field
Flow rate:
1 sprinkler at the sideline
Q= 6,5 m³/h
1 sprinkler in the centre of the field
Q= 6,5 m³/h
Max. flow rate per irrigation section
Q= 13,0 m³/h
Operating pressure:
Pressure at the sprinkler nozzle
H = 6,0 bar
Required flow pressure at the connecting terminal for a water intake of 18,4 m³/h
H = 8,0 bar
Precipitation:
Average precipitation density
1,8 mm/h
No. of sprinklers:
Lateral sprinkler: HYDRA-2-M WVAC
12 pieces
Midfield sprinkler: HYDRA-2-M TC
6 pieces
Controller: WaterControl+ SC 12 stations
1 piece
Solenoid valve: MVR 1"
6 pieces